Any electrical leak can be dangerous for your staff and production site. By using IVY Residual Current Device (RCD) you can protect both staff and equipment. Thanks to its zero-flux technology expertise, IVY developed a range of highly flexible Residual Current Monitor of Type B/B+ for measuring DC and AC residual currents up to 100kHz, with digital signal output.
MD0630T01A-Z sensor is a new, compact, horizontal type rcd current sensor with pins designed for use in e-mobility infrastructure and AC charging station designs to monitor leakage currents in mode two/three/four electric vehicle charging. MD0630T01A-Z Type A, B and B+ RCD, dedicated to detect to DC, AC and DC+AC leakage current measurement. The sensor can issues an alarm signal when the DC component of the residual current reaches a preset value.
Product Introduction
MD0630T01A-Z is an automotive grade leakage current sensor also called residual current monitoring (RCM), residual current detection (RCD), differential current sensor, leakage current detector and fault current sensor. It has the characteristics of accurate measurement, small size and integration. The RCD sensor can be set separately for AC and DC leakage and has a digital output function. It can detect sinusoidal AC, pulsating DC, composite of multi-frequency as well as smooth DC residual currents. Widely used for electro-medical instruments, ventilation systems, inverters, UPS, Electric vehicle charging stations, power distribution unit(PDU), water heater, smart home, industrial machines, solar panle etc. In addition, our delivery time is also guaranteed.
Main Features:
mA Level Measurement, AC DC Leakage Data Readable
Integrated Design, Horizontal Installation, with Pin/PCB
Alarm Value Programmable, 3 Types of alarm Outputs
UART Serial Communication, Modbus Protocol
TUV Certificate IEC62955:2018 (IEC 61008-1:2010+A1:2012+A2:2013)
CE-EMC: EN 61000-6-3:2007+A1 ,EN IEC 61000-6-1:2019
Product Parameters
Wide voltage input: 12V±20%
Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)
Accuracy : at 25℃, DC±0,2mA, AC±0.3mA
Can read current value and set alarm current value
Three outputs: DC alarm, AC alarm, AC/DC alarm
Working environment temperature: -25℃~+80℃
Plastic case, small SIP package
Leakage Current Detection Type:
Pin Definition
Pin | Definition | Description |
1 | Vcc | 12V±20% input voltage |
2 | GND | Input terminal grounded |
3 | RX | UART receive(UART output voltage 5V)(Modbus Protocol) |
4 | TX | UART transmit(UART output voltage 5V)(Modbus Protocol) |
5 | AD | AC、DC leakage alarming output( output voltage 5V)(Digital Signal) |
6 | AO | AC leakage alarming output( output voltage 5V)(Digital Signal) |
7 | DO | DC leakage alarming output(output voltage 5V)(Digital Signal) |