MD36DA-C is a residual direct current monitoring device with the characteristics of high sensitivity, accurate measurement, small size, and integration. When a DC leakage current of 3~6mA is detected, an alarm signal is output. It has a self-test function, which can be used to judge whether the sensor is in a normal working state in real time. If the sensor fails, the self-test output terminal will not be able to output a feedback signal. This DC RCD can detect smooth DC and half-wave DC currents.
Product Description
MD36DA-C is a pin type RDC-DD, which can also be called leakage current sensor, residual current sensor, residual current monitor (RCM), residual current device (RCD), differential current sensor. With digital output of fault detection and integrated self-testing functions. The sensor can be used to build an IEC62955 Residual Direct Current - Detecting Device (RDC-DD) together with EV charging controller and switching devices inside EV chargers, which can meet AC/DC residual current protection request defined in IEC 61851-1 & IEC 60364-7-722.
IVY MD series RCDs are optimized for fast, cost-effective assembly, combined with the highest product and production quality. In addition to the use of charging piles. Also suitable for solar inverters, UPS, power distribution cabinet, marine power board, smart home, industrial machines etc. There is a DC component leakage scenario. Provide more reliable protection. Protecting personal and electrical equipment safety.
Product Dimension
Product Parameters
Voltage | 12V±20% (Current about 12mA) |
Current | DC current 2~15mA/AC current 3~100mA |
Alarm Current Range | DC 3~6mA/AC 15~30mA |
Alarm Output | Open Collector |
Operation Temperature Range | -25~+80℃ |
Installation | PCB/Pin/Vertical Type |
Appearance | Plastic casing V0 |
Product Applications
1.Being able to detect smooth DC residual currents which can occur in EV charger stations and photovoltaic systems, IVY RCD guarantees the safety of the people and of the installation
2.can guarantee dependable protection for field technicians and installed machinery by detecting high frequency residual current and protecting against smooth DC residual currents in the event of a fault.
3.can prevent damage to installed equipment and avoid operational impacts in situations where service interruption and out of order can cause discomfort.
4.In installation where we cannot necessarily withstand any sort of interruption, IVY RCD can minimize outages, equipment damage, failures and interruption of any critical operation