IVY MD0630T01A AC DC Leakage Current Sensor

·High-Precision Measurement

Accuracy of ±0.2mA for DC and ±0.3mA for AC
·Comprehensive AC/DC Detection

Senses both smooth DC and sinusoidal AC residual currents
·Settable Alarm Thresholds

Default alarms at 6mA DC / 30mA AC
·Digital & Communication Output

Switch control alarm signal and a UART digital interface
·Wide Range of Applications

EVSE, energy storage systems, medical instruments, and smart grids

Product Details

Product Description

This product is fully compliant with TUV/CE-EMC 
The MD0630T01A is a residual current monitor intended for the detection of DC and AC residual currents in 50Hz/60Hz AC installations.
The MD0630T01A is primarily intended for use in Mode 2 Electric Vehicle In-Cable Control and Protection Devices (IC-CPDs) and Mode 3 Wallbox Charger, to disconnect the supply to the Electric Vehicle under an AC or DC residual current fault condition.
The MD0630T01A may also be used to detect DC or AC residual currents in DC, single-phase phase or multiphase installations.
The MD0630T01A is a compact solution designed to be mounted directly onto a PCB.


MD0630T01A Vertical Differential Earth Leak Detection Current Sensor Type B RCD for EVSE on-board Charger


Product Features

1. Complies with the DC and AC protection requirements of IEC62752 or IEC62955

2. Small Size, Integration Design, Vertical/Horizontal Mounting Optional

3. AC DC Leakage Data Readable, Alarm Value Programmable, 3 Way Alarm Outputs

4. UART Comm, with Modbus Protocol, Type B RCD/RCMU Protection

5. Standard: TUV(IEC62955/IEC62752/IEC61851-1), UL2231-1/UL2231-2, IS17017, CE-EMC 

6. Electrical Safety at Cost-effective (Compared to Type B RCCB)

7. Robust Mechanical and Electrical Design for Harsh Environmental Conditions


Pin Definition

Pin

Definition

Description

1

Vcc

12V±20% input voltage

2

GND

Input terminal grounded

3

RX

UART receive

     (UART output voltage 5V)(Modbus Protocol)

4

TX

UART transmit

     (UART output voltage 5V)(Modbus Protocol)

5

AD

AC、DC leakage alarming output

                ( output voltage 5V)(Digital Signal)

6

AO

AC leakage alarming output

                ( output voltage 5V)(Digital Signal)

7

DO

DC leakage alarming output

              (output voltage 5V)(Digital Signal)


Why is RCD required in IC-CPD and AC Charger applications?

The existing type A RCD can only in the detection of pulsating DC leakage from 6 mA DC interference, and can’t detect DC leakage and disconnect protection, when DC leakage is more than 6 mA, due to the DC residual current will cause core magnetization in advance, resulting in tripping value deviation, leading to the type A RCD can’t normal movement. 

Therefore, type B RCD or A+6mA protection must be used!

MD0630T01A EVSE 12V Supply Voltage GFCI Leakage Protection RCD Current Sensor with 6mA DC Detection


Product Parameters

  • Wide voltage input: 12V±20%

  • Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)

  • Accuracy : at 25℃, DC±0,2mA, AC±0.3mA

  • Can read the current value and set the alarm's current value

  • Three outputs: DC alarm, AC alarm, AC/DC alarm

  • Working environment temperature: -25℃~+80℃

  • Plastic case, small SIP package


Typical Application

  • Appliance ground fault detection

  • Solar inverter residual current 

  • Converter leakage current detection 

  • UPS and other power ground fault detection

  • Electric vehicle charging station

  • Single or 3-phase differential current detection