·High-Precision Measurement
Accuracy of ±0.2mA for DC and ±0.3mA for AC
·Comprehensive AC/DC Detection
Senses both smooth DC and sinusoidal AC residual currents
·Settable Alarm Thresholds
Default alarms at 6mA DC / 30mA AC
·Digital & Communication Output
Switch control alarm signal and a UART digital interface
·Wide Range of Applications
EVSE, energy storage systems, medical instruments, and smart grids
Product Description
This product is fully compliant with TUV/CE-EMC
The MD0630T01A is a residual current monitor intended for the detection of DC and AC residual currents in 50Hz/60Hz AC installations.
The MD0630T01A is primarily intended for use in Mode 2 Electric Vehicle In-Cable Control and Protection Devices (IC-CPDs) and Mode 3 Wallbox Charger, to disconnect the supply to the Electric Vehicle under an AC or DC residual current fault condition.
The MD0630T01A may also be used to detect DC or AC residual currents in DC, single-phase phase or multiphase installations.
The MD0630T01A is a compact solution designed to be mounted directly onto a PCB.
Product Features
1. Complies with the DC and AC protection requirements of IEC62752 or IEC62955
2. Small Size, Integration Design, Vertical/Horizontal Mounting Optional
3. AC DC Leakage Data Readable, Alarm Value Programmable, 3 Way Alarm Outputs
4. UART Comm, with Modbus Protocol, Type B RCD/RCMU Protection
5. Standard: TUV(IEC62955/IEC62752/IEC61851-1), UL2231-1/UL2231-2, IS17017, CE-EMC
6. Electrical Safety at Cost-effective (Compared to Type B RCCB)
7. Robust Mechanical and Electrical Design for Harsh Environmental Conditions
Pin Definition
Pin | Definition | Description |
1 | Vcc | 12V±20% input voltage |
2 | GND | Input terminal grounded |
3 | RX | UART receive (UART output voltage 5V)(Modbus Protocol) |
4 | TX | UART transmit (UART output voltage 5V)(Modbus Protocol) |
5 | AD | AC、DC leakage alarming output ( output voltage 5V)(Digital Signal) |
6 | AO | AC leakage alarming output ( output voltage 5V)(Digital Signal) |
7 | DO | DC leakage alarming output (output voltage 5V)(Digital Signal) |
Why is RCD required in IC-CPD and AC Charger applications?
The existing type A RCD can only in the detection of pulsating DC leakage from 6 mA DC interference, and can’t detect DC leakage and disconnect protection, when DC leakage is more than 6 mA, due to the DC residual current will cause core magnetization in advance, resulting in tripping value deviation, leading to the type A RCD can’t normal movement.
Therefore, type B RCD or A+6mA protection must be used!
Product Parameters
Wide voltage input: 12V±20%
Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)
Accuracy : at 25℃, DC±0,2mA, AC±0.3mA
Can read the current value and set the alarm's current value
Three outputs: DC alarm, AC alarm, AC/DC alarm
Working environment temperature: -25℃~+80℃
Plastic case, small SIP package
Typical Application
Appliance ground fault detection
Solar inverter residual current
Converter leakage current detection
UPS and other power ground fault detection
Electric vehicle charging station
Single or 3-phase differential current detection