·mA Level Measurement, AC DC Leakage Data Readable
·Integrated Design, Horizontal Installation, with Pin/PCB
·Alarm Value Programmable, 3 Types of alarm Outputs
·UART Serial Communication, Modbus Protocol
·TUV Certificate IEC62955:2018 (IEC 61008-1:2010+A1:2012+A2:2013)
·CE-EMC: EN 61000-6-3:2007+A1, EN IEC 61000-6-1:2019
Main Features
·mA Level Measurement, AC DC Leakage Data Readable
·Integrated Design, Horizontal Installation, with Pin/PCB
·Alarm Value Programmable, 3 Types of Alarm Outputs
·UART Serial Communication, Modbus Protocol
·TUV Certificate IEC62955:2018 (IEC 61008-1:2010+A1:2012+A2:2013)
·CE-EMC: EN 61000-6-3:2007+A1, EN IEC 61000-6-1:2019

Product Parameters
Wide voltage input: 12V±20%
Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)
Accuracy: at 25℃, DC±0,2mA, AC±0.3mA
Can read current value and set alarm current value
Three outputs: DC alarm, AC alarm, AC/DC alarm
Working environment temperature: -25℃~+80℃
Plastic case, small SIP package

1. Being able to detect smooth DC residual currents, which can occur in EV charger stations and photovoltaic systems, IVY RCD guarantees the safety of the people and the installation
2. Can guarantee dependable protection for field technicians and installed machinery by detecting high-frequency residual current and protecting against smooth DC residual currents in the event of a fault.
3. Can prevent damage to installed equipment and avoid operational impacts in situations where service interruption and out of-order can cause discomfort.
4. In installations where we cannot necessarily withstand any sort of interruption, IVY RCD can minimize outages, equipment damage, failures, and interruption of any critical operation
Leakage Current Detection Type

Pin Definition

Pin | Definition | Description |
1 | Vcc | 12V±20% input voltage |
2 | GND | Input terminal grounded |
3 | RX | UART receive(UART output voltage 5V)(Modbus Protocol) |
4 | TX | UART transmit(UART output voltage 5V)(Modbus Protocol) |
5 | AD | AC、DC leakage alarming output( output voltage 5V)(Digital Signal) |
6 | AO | AC leakage alarming output( output voltage 5V)(Digital Signal) |
7 | DO | DC leakage alarming output(output voltage 5V)(Digital Signal) |
EM613005 9-60VDC Powered Solar Bidirectional RS485 DC Volt Amp Watt meter for 48VDC Battey System