MD0630T01A-Z IEC61851-1 Horizontal Pin Mount Type B RCMU AC DC Residual Current Monitoring for EV Charger

·mA Level Measurement, AC DC Leakage Data Readable

·Integrated Design, Horizontal Installation, with Pin/PCB

·Alarm Value Programmable, 3 Types of alarm Outputs

·UART Serial Communication, Modbus Protocol

·TUV Certificate IEC62955:2018 (IEC 61008-1:2010+A1:2012+A2:2013)

·CE-EMC: EN 61000-6-3:2007+A1, EN IEC 61000-6-1:2019

Product Details

Main Features

·mA Level Measurement, AC DC Leakage Data Readable

·Integrated Design, Horizontal Installation, with Pin/PCB

·Alarm Value Programmable, 3 Types of Alarm Outputs

·UART Serial Communication, Modbus Protocol

·TUV Certificate IEC62955:2018 (IEC 61008-1:2010+A1:2012+A2:2013)

·CE-EMC: EN 61000-6-3:2007+A1, EN IEC 61000-6-1:2019


EV Charger Parts Compact 6mA DC 30mA AC Leakage Current Detector RCD Sensor with Pins


Product Parameters

  • Wide voltage input: 12V±20%

  • Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)

  • Accuracy: at 25℃, DC±0,2mA, AC±0.3mA

  • Can read current value and set alarm current value

  • Three outputs: DC alarm, AC alarm, AC/DC alarm

  • Working environment temperature: -25℃~+80℃

  • Plastic case, small SIP package


MD0630T01A-Z EV 6mA 30mA RCM AC DC Leakage Protection Residual Current Monitoring Unit RCD Sensor


1. Being able to detect smooth DC residual currents, which can occur in EV charger stations and photovoltaic systems, IVY RCD guarantees the safety of the people and the installation

2. Can guarantee dependable protection for field technicians and installed machinery by detecting high-frequency residual current and protecting against smooth DC residual currents in the event of a fault.

3. Can prevent damage to installed equipment and avoid operational impacts in situations where service interruption and out of-order can cause discomfort.

4. In installations where we cannot necessarily withstand any sort of interruption, IVY RCD can minimize outages, equipment damage, failures, and interruption of any critical operation


Leakage Current Detection Type

image.png


Pin Definition

image.png

Pin

Definition

Description

1

Vcc

12V±20% input voltage

2

GND

Input terminal grounded

3

RX

UART receive(UART output voltage 5V)(Modbus Protocol)

4

TX 

UART transmit(UART output voltage 5V)(Modbus Protocol)

5

AD

AC、DC leakage alarming output( output voltage 5V)(Digital Signal)

6

AO 

AC leakage alarming output( output voltage 5V)(Digital Signal)

7

DO

DC leakage alarming output(output voltage 5V)(Digital Signal)