Any electrical leak can be dangerous for your staff and production site. By using IVY Residual Current Device (RCD) you can protect both staff and equipment. IVY developed a range of highly flexible Residual Current Monitor of Type AC/A/B/B+ for measuring DC and AC residual currents up to 100kHz, with digital signal output.
MD0630STA-C is a cost-effective leakage current sensor, which can also be called residual current sensor, residual current monitor (RCM), residual current detection (RCD), differential current sensor, zero phase current transformer, fault current sensor etc.
Product Description
MD0630STA-C is an AC DC residual current monitor with the characteristics of high sensitivity, accurate measurement, small size, and integration. When a DC leakage current of 3~6mA or an AC leakage current of 15~30mA is detected, an alarm signal will be output. At the same time, it has a self-test function, which can be used to judge in real time whether the sensor is in a normal working state. If the sensor fails, the self-test output terminal will not be able to output a feedback signal.
It can not only detect AC fault current, DC pulsing and smooth DC fault current, but also sinus wave AC fault current at a high frequency up to 1kHz. IVY MD series leakage current sensors are optimized for fast, low-cost assembly, combined with the highest product and production quality. In addition to the use of charging piles. Also suitable for inverters, UPS, smart home, industrial machines, photovoltaic systems, power distribution cabinet etc. Provide more reliable protection. Protecting personal and electrical equipment safety.
Product Advantages
DC 2~15mA/AC 3~100mA micro current detection
DC 3~6mA/AC 15~30mA Alarm (Needn’t Set)
Self-test Function, Open Collector Alarm Output
Integrated Design, Cable/Horizontal Type Installation
Type B Leakage Current Detection
Comply with IEC/UL Standard
Cost-effective Design
Product Dimension
Product Application
1.Being able to detect smooth DC residual currents which can occur in EV charger stations and photovoltaic systems, IVY RCD guarantees the safety of the people and of the installation
2.can guarantee dependable protection for field technicians and installed machinery by detecting high frequency residual current and protecting against smooth DC residual currents in the event of a fault.
3.can prevent damage to installed equipment and avoid operational impacts in situations where service interruption and out of order can cause discomfort.
4.In installation where we cannot necessarily withstand any sort of interruption, IVY RCD can minimize outages, equipment damage, failures and interruption of any critical operation