·mA Level Measurement, AC DC Leakage Data Readable
·Integrated Design, Horizontal Installation, with Pin/PCB
·Alarm Value Programmable, 3 Types of alarm Outputs
·UART Serial Communication, Modbus Protocol
·TUV Certificate IEC62955:2018
·CE-EMC: EN 61000-6-3:2007+A1, EN IEC 61000-6-1:2019
Product Introduction
MD0630T01A-Z is an automotive grade leakage current sensor also called residual current monitoring (RCM), residual current detection (RCD), differential current sensor, leakage current detector, and fault current sensor. It has the characteristics of accurate measurement, small size, and integration. The RCD sensor can be set separately for AC and DC leakage and has a digital output function.
It can detect sinusoidal AC, pulsating DC, composite of multi-frequency as well as smooth DC residual currents. Widely used for electro-medical instruments, ventilation systems, inverters, UPS, Electric vehicle charging stations, lifts, escalators, welding equipment, smart homes, industrial machines, elevators, IOT, and photovoltaic systems. In addition, our delivery time is also guaranteed.
Main Features
·mA Level Measurement, AC DC Leakage Data Readable
·Integrated Design, Horizontal Installation, with Pin/PCB
·Alarm Value Programmable, 3 Types of alarm Outputs
·UART Serial Communication, Modbus Protocol
·TUV Certificate IEC62955:2018 (IEC 61008-1:2010+A1:2012+A2:2013)
·CE-EMC: EN 61000-6-3:2007+A1 ,EN IEC 61000-6-1:2019
1. Being able to detect smooth DC residual currents, which can occur in EV charger stations and photovoltaic systems, IVY RCD guarantees the safety of the people and the installation
2. Can guarantee dependable protection for field technicians and installed machinery by detecting high-frequency residual current and protecting against smooth DC residual currents in the event of a fault.
3. Can prevent damage to installed equipment and avoid operational impacts in situations where service interruption and being out of order can cause discomfort.
4. In installations where we cannot necessarily withstand any sort of interruption, IVY RCD can minimize outages, equipment damage, failures, and interruption of any critical operation
Pin Definition
Pin | Definition | Description |
1 | Vcc | 12V±20% input voltage |
2 | GND | Input terminal grounded |
3 | RX | UART receive(UART output voltage 5V)(Modbus Protocol) |
4 | TX | UART transmit(UART output voltage 5V)(Modbus Protocol) |
5 | AD | AC、DC leakage alarming output( output voltage 5V)(Digital Signal) |
6 | AO | AC leakage alarming output( output voltage 5V)(Digital Signal) |
7 | DO | DC leakage alarming output(output voltage 5V)(Digital Signal) |
Leakage Current Detection Type
Dimension