·Comprehensive Measurement: A/R Energy (Multi-tariff), Power, V, I, F, PF, Max Demand.
·High Accuracy: Class B Active Energy.
·Flexible Comms: IR & RS485 (Modbus/DLT645), Config. Baud Rate.
·Multi-tariff & RTC: 4 Tariffs (T1-T4), Li-batt RTC.
·Configurable Outputs: 2 Pulse Outputs (A/R Energy).
·Robust Design: -40°C to 70°C, IP51 (Indoor).
·Standard Compliant: EN50470-1/3.
·Installation: DIN-rail Mount.
·Electrical Specs: 5(100)A, 3*230/400V.
·Display: Backlit LCD (6+2 Digits).
·Measurable instantaneous parameters include voltage, current, active power, reactive power, apparent power, frequency, and power factor.
·Measurable power parameters include: total active power, total reactive power, total forward active power, total reverse active power, T1-T4 forward active power, T1-T4 forward reactive power, T1-T4 reverse active power, T1-T4 reverse reactive power, T1-T4 active power, T1-T4 reactive power, T1-T4 four-quadrant reactive power, resettable total active and reactive power, forward and reverse active and reactive demand, and maximum demand, etc.
·LCD backlight display, data scrolling display, manual page turning through buttons
·Supports RS485 communication, reads meter parameters
·Standard guide rail installation
Parameter
Nominal Voltage (Un) | 3*230(400)VAC |
Current | 5(100)A |
Starting Current | 0.4% Ib |
Power Consumption | < 12VA, < 1W |
Accuracy Class | Class B |
Frequency | 50Hz |
Pulse Output (LED) | 1000 imp/kWh, 1000 imp/kvarh |
Display | LCD 6+2 digits (Max 999999.99 kWh) |
Operating Temperature | -40°C to +70°C |
Relative Humidity | ≤75% (Non-condensing) |
Protection Rating | IP51 (Indoor use only) |
Reference Standard(s) | EN50470-1 / EN50470-3 |
·Support RS485 communication, Modbus protocol, and DLT645-2007 protocol compatibility; the meter can read the meter and the meter parameters through RS485 communication.
·Baud rate 9600\19200\38400\115200 can be set, the default is 9600bps;
·Default setting 9600/NONE /8/1;
·The enclosure is sealed; do not open the meter enclosure. If the enclosure has been opened, the warranty is void.
·The meter should be installed in an indoor or outdoor meter box.
·According to Directive 2014/32/EU, the meter is intended to be installed in the mechanical environment ‘M1’ with low shock and vibration levels.
·According to Directive 2014/32/EU, the meter is intended to be installed in the electromagnetic environment ‘E2’.
·Isolation safety information: The meter utilizes local power generation, and the main power supply must be disconnected before installation and removal. Improper operation may cause personal injury or damage to equipment.
·This meter is a direct meter and can be directly used with a UC rating, i.e., UC2 (≤100A)