Any electrical leak can be dangerous for your staff and production site. By using IVY Residual Current Monitor (RCM) you can protect both staff and equipment. IVY developed a range of highly flexible Residual Current Monitor of Type AC/A/B/B+ for measuring DC and AC residual currents up to 100kHz, with digital signal output.
MD0630STA-C is a cost-effective leakage current sensor, which can also be called residual current sensor, residual current monitor (RCM), residual current device (RCD), differential current sensor, earth leakage current detector, fault current sensor etc.
Quick answer: The IVY MD0630STA-C is a cost-effective AC/DC leakage current sensor, also called a residual current sensor, residual current monitor (RCM), residual current device (RCD), differential current sensor, earth leakage current detector or fault current sensor. It detects AC fault current, pulsating DC, smooth DC and sinusoidal AC up to 1 kHz, measures DC 2–15 mA / AC 3–100 mA, and asserts an open-collector alarm at a factory-set DC 3–6 mA or AC 15–30 mA. A built-in self-test verifies normal operation. Designed for EV charging and equipment with a DC leakage component, it is a compact alternative to a Type B RCCB and is designed for IEC 62752, IEC 62955 and UL 2231 applications.
Definition: A Type B RCD / RCM is a residual current detection device that senses AC, pulsating DC and smooth DC fault currents. The MD0630STA-C provides the detection and alarm stage; the system contactor or switching device performs disconnection.
Product — Type B RCD / RCM leakage current sensor for EV chargers and AC/DC leakage monitoring.
Detection — AC, pulsating DC, smooth DC and sinusoidal AC up to 1 kHz; range DC 2–15 mA / AC 3–100 mA.
Alarm — DC 3–6 mA / AC 15–30 mA, factory set, no adjustment required.
Output — Open-collector alarm; built-in self-test with feedback terminal.
Mounting — Integrated design, cable / horizontal type installation.
Cost — Lower cost electrical safety than a Type B RCCB.
Standards — Designed for IEC 62752, IEC 62955 and UL 2231.
| Parameter | Specification |
|---|---|
| Model | MD0630STA-C |
| Device type | Type B RCD / RCM, AC/DC leakage current sensor |
| Detection range | DC 2–15 mA; AC 3–100 mA |
| Alarm threshold | DC 3–6 mA; AC 15–30 mA (factory set, no setting required) |
| Detectable current | AC, pulsating DC, smooth DC, sinusoidal AC up to 1 kHz |
| Output | Open-collector alarm signal |
| Self-test | Built-in; feedback signal absent if the sensor fails |
| Installation | Integrated design, cable / horizontal type |
| Design | High sensitivity, accurate measurement, small size, robust mechanical and electrical construction |
| Standards (design reference) | IEC 62752, IEC 62955, UL 2231 |
When a residual current arises, the MD0630STA-C senses both the AC and DC components and compares them with its factory-set thresholds. If the DC leakage reaches 3–6 mA or the AC leakage reaches 15–30 mA, the alarm output is activated. The connected controller can then open the contactor, flag an error and lock out the equipment until reset.
The self-test function checks the detection and alarm chain in real time. If the sensor is faulty, the self-test output terminal cannot provide a feedback signal, allowing installers and maintenance engineers to identify a failed device before it is relied upon for protection.
Smooth DC residual current can occur in EV chargers, photovoltaic systems, UPS, welding equipment and DC panels. A conventional Type A or Type F device may not respond reliably when DC pre-magnetizes its core. The MD0630STA-C detects AC, pulsating DC and smooth DC, as well as sinusoidal AC up to 1 kHz, giving designers a single sensing element for Type B leakage monitoring.
A Type B RCCB is a complete protective device with its own enclosure, terminals and trip mechanism. The MD0630STA-C provides the sensing and alarm function as a compact component for equipment that already has a controller and switching device. This removes a second enclosure, extra wiring and a separate DIN-rail device, reducing cost while maintaining electrical safety.
EV charging: AC charging piles, wallboxes, Mode 2 and Mode 3 charging equipment, charging control panels.
Renewable energy: Solar inverters and photovoltaic systems with DC leakage components.
Power electronics: UPS, welding equipment, DC panels and power distribution cabinets.
Medical and building systems: Medical instruments where leakage monitoring supports personnel safety.
Industrial and residential: Smart home panels, industrial machines and other installations where service interruption, equipment damage or nuisance outages must be minimized.
What is the MD0630STA-C used for?
It is a Type B RCD / RCM leakage current sensor for EV chargers and other equipment where AC and DC residual currents must be monitored.
Does it detect smooth DC fault current?
Yes. It detects AC fault current, pulsating DC, smooth DC and sinusoidal AC up to 1 kHz.
What is the detection range?
DC 2–15 mA and AC 3–100 mA.
Does the alarm threshold need to be set on site?
No. The alarm is factory set to DC 3–6 mA / AC 15–30 mA.
What output does it provide?
An open-collector alarm signal. A built-in self-test output provides feedback on the sensor's working state.
Can it replace a Type B RCCB?
It provides the detection function, not the switching. The system's contactor or switching device performs disconnection, so it replaces the detection stage rather than the complete RCCB.
How is it installed?
It uses an integrated design with cable / horizontal type installation.
Which standards does it reference?
IEC 62752, IEC 62955 and UL 2231.
Where else can it be used besides EV chargers?
Solar inverters, medical instruments, UPS, welding equipment, smart home systems, industrial machines, DC panels and power distribution cabinets.