-
EM519033 Forward and Reverse Din Rail 3 Phase RS485 Modbus MID Energy Meter for EV Charger
EM519033 is a 80A 100A three-phase four-wire electric energy meter with rates. This EV meter adopts IR & RS485 communication,multi-tariff,DIN rail installation, and has bidirectional measurement function (active forward and reserved measurement). This AC ev charging meter can also visually display the voltage, current, power, voltage, current,
Inquire Now
-
EM519032 MID Approved Electric Car Charging 3 Phase Smart Bidirectional Energy Meter with RS485 Modbus
EM519032 is a 80A three-phase four-wire din rail mounted kwh meter. This EV meter adopts DIN rail installation, and has bidirectional measurement function (active forward and reserved measurement). This AC ev charging meter can also visually display the voltage, current, power, voltage, current, It is convenient to query all kinds of data and view
Inquire Now
-
MD0630T41A-1 EV Charging Station Components AC DC Leakage Current Monitoring Residual Fluxgate Sensor
MD0630T41A-1 RCD is designed for use in e-mobility infrastructure and AC/DC charging station to monitor leakage currents in mode two/three/four electric vehicle charging. It is a residual current monitor with high sensitivity, mA level measurement, small size, integrated design, cable/horizontal installation.
Inquire Now
-
MD0630T01A-2 Small Pin Type RCMU Protection 6mA DC Earth Leakage Current Detector for 22KW AC Charger
MD0630T01A-2 is an ultra-miniature AC DC leakage sensor for AC portable ev charger, which has the characteristics of accurate measurement, high sensitivity, digital signal, push-pull output, and integrated design, measuring current range DC current: 2~15mA; Maximum AC current: 3~100mA (default threshold: DC 6mA, AC 30mA)
Inquire Now
-
EM619001 150A 1000V MID Din Rail Data Logger Bidirectional DC Power Meter for DC Charging Station
EM619001 dc energy meter is designed for measuring and monitoring in DC systems, especially for the DC EV chargers. The din rail DC energy meters can measure of important DC parameters: voltage, current, power and energy etc. It also support bi-directional measurement with pulse output. All data in the meter are accessible via RS485 using Modbus.
Inquire Now
-
MD0630T41A Integrated 6mA DC RCD Protection Leakage Sensor Differential Current Transformer for AC Charger
MD0630T41A is a DC/AC leakage current sensor with high sensitivity, accurate measurement, small size, integration, digital output, UART communication, Modbus protocol, etc. The measurement DC current range is 2~15mA, the AC current range is 3~100mA, Type B detection is worth to be mentioned too.
Inquire Now
-
IVY-CT-PCB-01-10A High Precision Single Phase 50/60Hz 220V AC 40A 60A PCB Mount CT Current Transformer
IVY-CT-PCB-01-10A is a pcb mounted current transformer, the max current can also be made into 50A and 60A. The advantages of this PCB ct are: small size, high accuracy of 0.1 class, good consistency, 3000V dielectric strength, low phase error etc. They are mainly used for current and power sampling and measurement.
Inquire Now
-
MD0630T01A IEC62955 AC DC Leakage Detector Internal Type B EV RCD 6mA 30mA Residual Current Device
MD0630T01A is a residual current detection RCD sensor, When an electric shock or leakage fault occurs in the circuit, the secondary side of the transformer outputs a mA level current (DC 6mA, AC 30mA), so that the equipment on the connected secondary line will be protected (cut off the power supply, alarm signal, etc.)
Inquire Now
-
EM519024 3 Phase Bidirectional V2G 63A Three phase digital MID Energy Meters
EM519033 is a 80A 100A three-phase four-wire electric energy meter with rates. This EV meter adopts IR & RS485 communication,multi-tariff,DIN rail installation, and has bidirectional measurement function (active forward and reserved measurement). This AC ev charging meter can also visually display the voltage, current, power, voltage, current,
Inquire Now
-
EM519033 MID Approved 3 Phase 400V 80A Modbus Bidirectional Power Metering EV Charging Smart Meter
EM519033 is a 80A three-phase four-wire electric energy meter with rates. This EV meter adopts IR & RS485 communication, multi-tariff, DIN rail installation, and has bidirectional measurement function (active forward and reserved measurement). This AC ev charging meter can also visually display the voltage, current, power, voltage, current.
Inquire Now
-
EM519032 MID approved Modbus AC energy meters for every EV Charging
EM519032 is a 80A three-phase four-wire din rail mounted kwh meter. This EV meter adopts DIN rail installation, and has bidirectional measurement function (active forward and reserved measurement). This AC ev charging meter can also visually display the voltage, current, power, voltage, current, It is convenient to query all kinds of data and view
Inquire Now
-
MD0630T41A CE 6mA DC 30mA AC B Type Leakage Protection RCD Residual Current Monitor Device for EV Charger
MD0630T41A is a DC/AC leakage current sensor with high sensitivity, accurate measurement, small size, integration, digital output, UART communication, Modbus protocol, etc. The measurement DC current range is 2~15mA, the AC current range is 3~100mA, Type B detection is worth to be mentioned too.
Inquire Now