IM601 IEC62055-31 UC2 60A 250VAC 2 Coil 12VDC Single Pole Power Latch Relay for EV Charger
IM601- It has the characteristics of shock resistance, safety and reliability, long life, low power consumption, strong load capacity, small size and better performance than general electromagnetic relays. In addition to the above advantages, it also uses single and double coils to work.The maximum switching current of IM601A can reach 60A.
Inquire Now
-
MD0630T01A EV Charger Testing RCD Transformer 6mA DC 30mA AC Earth Leakage Current Detection Device
MD0630T01A is a residual current detection RCD sensor, When an electric shock or leakage fault occurs in the circuit, the secondary side of the transformer outputs a mA level current (DC 6mA, AC 30mA), so that the equipment on the connected secondary line will be protected (cut off the power supply, alarm signal, etc.)
Inquire Now
-
IM-NE802 100A 250VAC Coil 12VDC 3mm Contact Gap SPST Non-latching Power Relay for EV AC Charger
IM-NE802 is a EV Relay for AC Charging with max amperage of 63A/100A. The contact form is SPST type (single pole single throw) 1A (normally open) contacts. With the 3mm contact distances, the dielectric strength can reach 4000VAC. It also meet with IEC255 & GB8898 Standard with UL certified.
Inquire Now
-
MD0630T01A IEC62955 AC DC Leakage Detector Internal Type B EV RCD 6mA 30mA Residual Current Device
MD0630T01A is a residual current detection RCD sensor, When an electric shock or leakage fault occurs in the circuit, the secondary side of the transformer outputs a mA level current (DC 6mA, AC 30mA), so that the equipment on the connected secondary line will be protected (cut off the power supply, alarm signal, etc.)
Inquire Now
-
EM519033-04 MID Certified 3 Phase Din Rail Net Metering Solar Bidirectional Meter with RS485 Modbus
EM519033-04 AC energy meters is designed for measuring and monitoring in AC side of solar panels. This solar energy meter can measure all important electrical parameters: voltage, current, power and energy, etc. It also supports bi-directional measurement with pulse output. All data in the meter are accessible via RS485 using Modbus RTU protocol.
Inquire Now
-
EM519024 3 Phase Bidirectional V2G 63A Three phase digital MID Energy Meters
EM519033 is a 80A 100A three-phase four-wire electric energy meter with rates. This EV meter adopts IR & RS485 communication,multi-tariff,DIN rail installation, and has bidirectional measurement function (active forward and reserved measurement). This AC ev charging meter can also visually display the voltage, current, power, voltage, current,
Inquire Now
-
EM519033 MID Approved 3 Phase 400V 80A Modbus Bidirectional Power Metering EV Charging Smart Meter
EM519033 is a 80A three-phase four-wire electric energy meter with rates. This EV meter adopts IR & RS485 communication, multi-tariff, DIN rail installation, and has bidirectional measurement function (active forward and reserved measurement). This AC ev charging meter can also visually display the voltage, current, power, voltage, current.
Inquire Now
-
EM519032 MID approved Modbus AC energy meters for every EV Charging
EM519032 is a 80A three-phase four-wire din rail mounted kwh meter. This EV meter adopts DIN rail installation, and has bidirectional measurement function (active forward and reserved measurement). This AC ev charging meter can also visually display the voltage, current, power, voltage, current, It is convenient to query all kinds of data and view
Inquire Now
-
MD0630T41A CE 6mA DC 30mA AC B Type Leakage Protection RCD Residual Current Monitor Device for EV Charger
MD0630T41A is a DC/AC leakage current sensor with high sensitivity, accurate measurement, small size, integration, digital output, UART communication, Modbus protocol, etc. The measurement DC current range is 2~15mA, the AC current range is 3~100mA, Type B detection is worth to be mentioned too.
Inquire Now
-
MD0630T01A EV Charger RCMU Uart Modbus 6mA DC 30mA AC RCD Leakage Current Detection Sensor
MD0630T01A is a residual current detection RCD sensor, When an electric shock or leakage fault occurs in the circuit, the secondary side of the transformer outputs a mA level current (DC 6mA, AC 30mA), so that the equipment on the connected secondary line will be protected (cut off the power supply, alarm signal, etc.)
Inquire Now
-
EM613001 10-240A 40-400V Solar System Power Energy Monitor Smart DC Kwh Meter with RS485
EM613001 is a DC measuring device sampling by shunt. Support RS485 communication and upload data to the system platform through the communication between RS485 and concentrator ( PS: EM613002 - it’s NB concentrator which allows 25 pcs of RS485 DC meters).
Inquire Now
-
EM613005 10-240A din rail digital shunt dc electric power energy meter for EV charging pile station
EM613005 is a 1 channel direct current DC smart energy meter designed with advanced energy metering chip and SMT technology. With RS485 port, the meter can communicate with the computer to exchange the data. The meter is widely used widely used for monitoring and controlling energy flow in DC systems such as solar PV energy, wind turbine power...